Shearer operation safety technology

Shearer operation safety technology

1. The operators of machinery and equipment must be in good health and pass professional training exams. They can only operate independently after obtaining the operation certificate or special type of operation certificate issued by the relevant department. The student must work under the guidance of the master.

2. During mechanical operations, the operator must not leave the job without authorization or hand over the machine to a non-local operator. Do not allow irrelevant personnel to enter the work area and operating room. When working, ideas should be concentrated and non-drinking operations are strictly prohibited.

3. Both mechanical operators and cooperating personnel must wear labor protection articles in accordance with regulations, and long hair must not be exposed. Do not wear hard-soled shoes and slippers.

4. The machinery and equipment used for daily operations of two shifts or more shall be subject to transitional shifts. Operators should carefully fill in the shift record.

5. Before start-up, all parts should be checked for lubrication and tightening conditions. There should be no gaps in the cutters. After start-up, they should be idling for 1 to 2 minutes. After they are confirmed to be normal, they can be operated.

6. The thickness of the shear plate must not exceed the capacity specified by the shear. When narrowing the plate, a piece of wider steel plate should be pressed on the sheared plate so that when the vertical pressing device is dropped, the sheared plate can be pressed firmly.

7. The gap between the upper and lower cutters shall be adjusted according to the thickness of the sheared plate. The gap between the cutters shall not be greater than 5% of the thickness of the plate, and shall not be greater than 7% when the bevel is sheared. After the adjustment, the hand rotation and the empty vehicle operation test shall be applied.

8. Braking devices should be adjusted in time according to wear conditions.

9. When one or more people work, they must wait for the commander to send a signal to work. When the material is fed, it must be stopped after the scissors are stopped. It is forbidden to put his hand into the inside of the vertical pressing device.

10. When feeding, put, lay flat, put steady, fingers should not be close to the cutter and the pressure plate.

11. After the operation, cut off the power supply, lock the gate, wipe and lubricate.

96 Well PCR Plates

PCR plates, 96 Well PCR Plates, and 348 well plates are disposable consumables in the laboratory. They are widely used in genetics, biochemistry, immunology, medicine and other fields. They are not only used in basic research such as gene isolation, cloning and nucleic acid sequence analysis, but also Diagnosis of disease or any place where there is DNA or RNA.

The new line of white PCR products is designed specifically to optimize results when performing quantitative Real Time PCR (qPCR). The new 96 Well PCR plates are free of DNA, DNase, RNase, and other PCR inhibitors. 96 Well PCR plates have thin, uniform walls to ensure consistent, precise thermal transfer and excellent results.

96-Well PCR Plate,ABI 96 Well Plate,Half Skirted PCR Plate,Skirted PCR Plate,Full Skirted PCR Plate

Yong Yue Medical Technology(Kunshan) Co.,Ltd , https://www.yonyue.com